The FZK 011 mechanical thermostat is used for controlling heating and cooling equipment, fil- ter fans or signal devices where a higher degree of sensing accuracy is required. An integrated resistor (RF) can be connected to improve the switch temperature difference (see Option note).
Thermostat NC (normally closed) Thermostat opens on temperature rise - for regulating heaters or for switching signal devices. Comes with red temperature dial.
The LC013 is used as a signal contact to monitor fans or filter fans in stationary.self-contained Protection Class l enclosures. It can be connected to monitoring systems with remote control or can directly switch alarm devices
The MFR 012 electromechanical hygrostat is designed to control the relative humidity inside enclosures. When connected to an enclosure heater (dehumidifier), it will energize the heater at the humidity set point in order to raise the dew point.
NTL11A-2: Thermostat (normally closed); contact breaker for regulating heaters. NTL11B-2:Thermostat (normally open); contact maker for regulating of filter fans and heat exchangers or for switching signal devised when temperature limit has been exceeded.
The design of the REx 011 Hazardous area Thermostat ensures high accuracy,small switching difference(hysteresis) and a long service life. Because of the high switching capacity of the thermostat,heaters can usually be directly connected and switched without the need for additional relays.
The DIN rail mounted electrical receptacle can be quickly fitted and connected in enclosures allowing the use of auxiliary products such as hand lamps and power tools. The unit is available with and without fuse, and in many world outlet standards.
The SM 010 Electronic Relay is used for switching high powered DC operated equipment, such as heaters, up to 16 amps. A separate conventional switch contact is used as controller (e.g. thermostat, hygrostat). The electronic relay is available in DC 24 V and DC 48 V versions.
The ST 011 thermostat is an SPST regulator with a small hysteresis. The housing design ensures optimized air circulation around the sensor element. STO 011: NC / opens on temperature rise (red thumbwheel) - for regulating heaters or for switching signal devices when temperature has fallen below the minimum value.
TL10A: Thermostat (normally closed); contact breaker for regulating heaters. TL10B: Thermostat (normally open); contact maker for regulating of filter fans and heat exchangers or for switching signal devised when temperature limit has been exceeded.
TRTS 011: Thermostat (normally open); contact maker for regulating of filter fans and heat exchangers or for switching signal devises when temperature limit has been exceeded. The contact closes when temperature is rising.