Have any questions?
CONTACT US
RFP 018 Roof Filter Fan 177 - 338 cfm
RFP 018 Roof Filter Fan 177 - 338 cfm

RFP 018 Roof Filter Fan 177 - 338 cfm

Advantage

> Clean production environment

> Full automatic testing with various tests

> Standardized production process with trained workers

> Low failure ratio and 24-month warranty

> Strong R&D and engineering support

Request a Quote  
RFP 018 Roof Filter Fan 177 - 338 cfm
RFP 018 Roof Filter Fan 177 - 338 cfm

RFP 018 Roof Filter Fan 177 - 338 cfm

Very low noise
Minimal mounting depth
High air volume
High reliability
Time-saving installation

Roof filter fans and roof exhaust filters are used in enclosures from which warm air must be diverted due to increased heat development. The ready-to-connect and low-noise roof filter fan is used to expel warm air from within the enclosure. Alternatively, the roof exhaust filter provides passive ventilation. The RFP 018 series comes in two versions: one utilizes four small axial fans, improving reliability and maintaining continuous operations even if one of the fans should fail; the second uses a larger single high capacity fan.

 

Axial fans, ball bearing service life min. 50,000 h at 77 °F (25 °C) and 65 %RH
aluminum fan body, plastic rotor
Connection 3-pole term., AWG 14 (2.5 mm²), clamping torque 0.8 Nm max.
Housing Plastic, UL 94V-0, light grey;
weather and UV light resistant according to UL 746C (f1)
Filter mat G3 acc. to DIN EN 779, filtering degree 85 %
Filter material synthetic fiber with progressive construction, 
temperature resistant to 212 °F, self-extinguishing class F1; 
moisture resistant to 100 %RH, reusable - 
can be cleaned by washing or vacuuming
Operating / Storage temperature dependent on fan type
Protection class I (grounded)
Protection type IP32
Approvals VDE (230V only)
Important note: For reasons of pressure compensation, the roof filter fan must always
be operated in combination with another filter fan
(e.g. Part No. 01803.0-00) or a passive intake filter (e.g. Part No. 11803.0-00).

 

RFP 018 Roof Filter Fan

Part No. 0perating voltage Air volume, free blowing (w/ G3 filter mat) Average noise level (DIN EN ISO 4871) Mounting depth Enclosure cut-out Weight (approx.)
01860.0-00 AC 230 V, 50 Hz1) 177 cfm (300 m³/h) - 4 fans 55 db (A) 2.0” (52 mm) 9.8 x 9.8” 7.3 lbs. (3.3 kg)
01860.0-02 AC 120 V,60 Hz 203 cfm (345 m³/h) - 1 fan 55 db (A) 2.0” (52 mm) 9.8 x 9.8” 5.7 lbs. (2.6 kg)
01861.0-00 AC 230 V, 50 Hz1) 294 cfm (500 m³/h) - 4 fans 67 db (A) 4.2” (107 mm) 9.8 x 9.8” 7.3 lbs. (3.3 kg)
01861.0-02 AC 120 V, 60 Hz 338 cfm (575 m³/h) - 1 fan 67 db (A) 4.2” (107 mm) 9.8 x 9.8” 5.7 lbs. (2.6 kg)

 1) air volume increases by 15% when operating AC 230 V filter fans at 60 Hz

 

RFP 018 Roof Filter Fan

Part No. 0perating voltage Air volume, free blowing (w/ G3 filter mat) Average noise level (DIN EN ISO 4871) Mounting depth Enclosure cut-out Weight (approx.)
01860.0-00 AC 230 V, 50 Hz1) 177 cfm (300 m³/h) - 4 fans 55 db (A) 2.0” (52 mm) 9.8 x 9.8” 7.3 lbs. (3.3 kg)
01860.0-02 AC 120 V,60 Hz 203 cfm (345 m³/h) - 1 fan 55 db (A) 2.0” (52 mm) 9.8 x 9.8” 5.7 lbs. (2.6 kg)
01861.0-00 AC 230 V, 50 Hz1) 294 cfm (500 m³/h) - 4 fans 67 db (A) 4.2” (107 mm) 9.8 x 9.8” 7.3 lbs. (3.3 kg)
01861.0-02 AC 120 V, 60 Hz 338 cfm (575 m³/h) - 1 fan 67 db (A) 4.2” (107 mm) 9.8 x 9.8” 5.7 lbs. (2.6 kg)

1) air volume increases by 15% when operating AC 230 V filter fans at 60 Hz

 

REP 118 Roof Exhaust Filter

Part No. Mounting depth Enclosure cut-out Weight (approx.) Filter mat Protection type
11860.0-00 0.43” (11 mm) 9.8 x 9.8” 2.2 lbs. (1.0 kg) G3 acc. to DIN EN 779, filtering degree 85 %

 

FM 086 Filter Mats

Filter mat 11.1 x 11.1” (282 x 282 mm)
G3 (1 packing unit = 3 pcs.)  Part No. 08613.0-01

Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/ buyer in its final application.

Message Feedback
If you have any enquiry about quotation or cooperation,please free to email us at Winston or use the following enquiry form,Our sales representative will contact you within 24 hous.thank you for your interest in our products.
News Center
How can I test the foot switch after install?
To test a foot switch after repair, follow these steps:1. Visual Inspection: Check for any visible damage or loose parts. Make sure all components are correctly placed and secured。2. Connectivity Chec
2024-09-27
Can I repair a damaged foot switch myself?
Repairing a damaged foot switch can be a straightforward process if you have some basic knowledge of electrical systems and the necessary tools. Here are some steps you can follow to repair a foot swi
2024-09-27
Winston Exhibition
nverter, maybe everyone knows that there is such a thing and what it is used for, but
2024-04-25
Chinese frequency inverter manufacturer mainly introduced to you what is an inverter
Inverter, maybe everyone knows that there is such a thing and what it is used for, but if you introduce it to others, most of you may not know how to say it. Because there are many things we know in life but don’t understand it. Of course, I believe that people who understand electricity or decoration industries still know about frequency converters. Next, the Chinese frequency inverter manufacturer mainly introduces to you what is an inverter.
2024-04-22

GET A QUOTE

AFFORDABLE PRICE: AS A MANUFACTURER, WE GIVE YOU FACTORY PRICE
Contact Us For Free Sample
×