Have any questions?
CONTACT US
WOT 315A 400A Load Isolator Switch Disconnector
WOT 315A 400A Load Isolator Switch Disconnector
WOT 315A 400A Load Isolator Switch Disconnector
WOT 315A 400A Load Isolator Switch Disconnector
WOT 315A 400A Load Isolator Switch Disconnector
WOT 315A 400A Load Isolator Switch Disconnector

WOT 315A 400A Load Isolator Switch Disconnector

Advantage

> Clean production environment

> Full automatic testing with various tests

> Standardized production process with trained workers

> Low failure ratio and 24-month warranty

> Strong R&D and engineering support

Request a Quote  
WOT 315A 400A Load Isolator Switch Disconnector
WOT 315A 400A Load Isolator Switch Disconnector
WOT 315A 400A Load Isolator Switch Disconnector
WOT 315A 400A Load Isolator Switch Disconnector
WOT 315A 400A Load Isolator Switch Disconnector
WOT 315A 400A Load Isolator Switch Disconnector

* Load isolating switches are widely applied to distribution system and automation system in building, power, petrochemical and other industries.

* The acceleration mechanism with instantaneous release of spring storage achieves fast connection or separation, which has nothing to do with the speed of operation handle, and greatly improves the ability of extinguishing arc.

* The shell made of glass fiber reinforced unsaturated polyester resin has good flame retardancy, dielectric properties, carbonization resistance and impact resistance.

* The parallel double breakpoint contact has self cleaning effect.

* All contact materials are copper plated silver alloy with two separate contact surfaces.

* The distance is large.

* In the "O" position, you can use three locks to lock the handle at the same time, and reliably avoid misoperation.

* The switch is beautiful, novel and concise, with small volume and complete function.

 

 

 

Model

 

 

WOT315F

WOT400F

Rated insulation voltage and raged operational voltage AC20/DC20.

Dielectric strength.

Rated impulse withstand voltage.

Pollution degree 3

50Hz 1min.

V

KV

KV

1000

10

12

1000

10

12

Rated thermal current and rated operational current AC20/DC20

...with minimum conductor cross section

Free air.

Closed environmen.

Cu.

A

A

mm²

315

315

185

400

400

240

Rated operational current, AC-21A

≤500V

690V

1000V

A

A

A

315

315

315

400

400

400

Rated operational current, AC-22A

≤500V

690V

1000V

A

A

A

315

315

315

400

400

400

Rated operational current, AC-23A

≤500V

690V

1000V

A

A

A

315

315

200

400

400

200

Rated operational current/ poles in series,

DC-21A...23A

24...110V

220V

440V

660V

A

A

A

A

 

315/1

315/2

315/3

315/4

400/1

400/2

360/3

360/4

Rated operational current/ poles in series,

DC-21B

800V

1000V

A

A

 

315/5

315/6

400/5

400/6

Rated operational power, AC-23A

230V

400V

415V

500V

690V

KW

KW

KW

KW

KW

100

160

180

220

315

122

220

230

280

400

Rated breaking capacity, AC-23A

≤500V

690V

A

A

2520

2520

3200

3200

Rated conditional short-circuit current Ip

(R.M.S) and corresponding max.allowed

cut-off current îc.

The cut-off currentîc refers to values

listed by fuse manufacturers (single phase

test acc.to IEC60269)

100KA, 500V

gG/aM

KA

A

 

61.5

500/450

 

61.5

500/450

80KA, 690V

gG/aM

KA

A

59

500/500

59

500/500

Rated short-time withstand current(R.M.S)lcw

≤1000V, 0.15s

≤1000V, 0.25s

≤1000V, 1s

KA

KA

KA

31

24

15

31

24

15

Rated short circuit making capacity

≤1000V

KA

65

65

Rated capacitor power (the capacitor ratings

are limited by the fuse link.)

415V

500V

690V

kVAr

kVAr

kVAr

145

175

250

180

215

325

Power loss/pole

At rated operational current

W

6.5

10

Mechanical endurance

 

Oper

16000

16000

Weight without accessories

3P switch

kg

2.2

2.2

Terminal screw specifications

Terminal tightening torque

Operating torque

Metric thread (diameter*length).

Locking torque requirements.

3-pole isolation switch.

mm

Nm

Nm

M10/30

30-44

16

M10/30

30-44

16

 

 

Message Feedback
If you have any enquiry about quotation or cooperation,please free to email us at Winston or use the following enquiry form,Our sales representative will contact you within 24 hous.thank you for your interest in our products.
News Center
How can I test the foot switch after install?
To test a foot switch after repair, follow these steps:1. Visual Inspection: Check for any visible damage or loose parts. Make sure all components are correctly placed and secured。2. Connectivity Chec
2024-09-27
Can I repair a damaged foot switch myself?
Repairing a damaged foot switch can be a straightforward process if you have some basic knowledge of electrical systems and the necessary tools. Here are some steps you can follow to repair a foot swi
2024-09-27
Winston Exhibition
nverter, maybe everyone knows that there is such a thing and what it is used for, but
2024-04-25
Chinese frequency inverter manufacturer mainly introduced to you what is an inverter
Inverter, maybe everyone knows that there is such a thing and what it is used for, but if you introduce it to others, most of you may not know how to say it. Because there are many things we know in life but don’t understand it. Of course, I believe that people who understand electricity or decoration industries still know about frequency converters. Next, the Chinese frequency inverter manufacturer mainly introduces to you what is an inverter.
2024-04-22

GET A QUOTE

AFFORDABLE PRICE: AS A MANUFACTURER, WE GIVE YOU FACTORY PRICE
Contact Us For Free Sample
×