Have any questions?
CONTACT US
High Voltage WOT 630A 800A Load Isolating Switch
High Voltage WOT 630A 800A Load Isolating Switch
High Voltage WOT 630A 800A Load Isolating Switch
High Voltage WOT 630A 800A Load Isolating Switch
High Voltage WOT 630A 800A Load Isolating Switch
High Voltage WOT 630A 800A Load Isolating Switch

High Voltage WOT 630A 800A Load Isolating Switch

Advantage

> Clean production environment

> Full automatic testing with various tests

> Standardized production process with trained workers

> Low failure ratio and 24-month warranty

> Strong R&D and engineering support

Request a Quote  
High Voltage WOT 630A 800A Load Isolating Switch
High Voltage WOT 630A 800A Load Isolating Switch
High Voltage WOT 630A 800A Load Isolating Switch
High Voltage WOT 630A 800A Load Isolating Switch
High Voltage WOT 630A 800A Load Isolating Switch
High Voltage WOT 630A 800A Load Isolating Switch

Product Description

* Load isolating switches are widely applied to distribution system and automation system in building, power, petrochemical and other industries.

* The acceleration mechanism with instantaneous release of spring storage achieves fast connection or separation, which has nothing to do with the speed of operation handle, and greatly improves the ability of extinguishing arc.

* The shell made of glass fiber reinforced unsaturated polyester resin has good flame retardancy, dielectric properties, carbonization resistance and impact resistance.

* The parallel double breakpoint contact has self cleaning effect.

* All contact materials are copper plated silver alloy with two separate contact surfaces.

* The distance is large.

* In the "O" position, you can use three locks to lock the handle at the same time, and reliably avoid misoperation.

* The switch is beautiful, novel and concise, with small volume and complete function.

Compact structure Excellent performance

The most compact isolation solution

 


High Voltage WOT 630A 800A Load Isolating Switch

Technical data

Model

 

 

WOT630F

WOT800F

Rated insulation voltage and raged operational voltage AC20/DC20.

Dielectric strength.

Rated impulse withstand voltage.

Pollution degree 3

50Hz 1min.

V

KV

KV

1000

10

12

1000

10

12

Rated thermal current and rated operational current AC20/DC20

...with minimum conductor cross section

Free air.

Closed environmen.

Cu.

A

A

mm²

630

630

2*185

800

800

2*240

Rated operational current, AC-21A

≤500V

690V

1000V

A

A

A

630

630

630

800

800

800

Rated operational current, AC-22A

≤500V

690V

1000V

A

A

A

630

630

630

800

800

800

Rated operational current, AC-23A

≤500V

690V

1000V

A

A

A

630

630

400

800

800

400

Rated operational current/ poles in series,

DC-21A...23A

24...110V

220V

440V

660V

A

A

A

A

 

630/1

630/1

630/2

630/4

800/1

800/1

800/2

650/4

Rated operational current/ poles in series,

DC-21B

800V

1000V

A

A

 

600/5

600/6

600/5

600/6

Rated operational power, AC-23A

230V

400V

415V

500V

690V

KW

KW

KW

KW

KW

200

355

355

400

630

250

450

450

560

800

Rated breaking capacity, AC-23A

≤500V

690V

A

A

5040

5040

6400

6400

Rated conditional short-circuit current Ip

(R.M.S) and corresponding max.allowed

cut-off current îc.

The cut-off current  îc refers to values

listed by fuse manufacturers (single phase

test acc.to IEC60269)

100KA, 500V

gG/aM 

KA

90

800/1000

90

800/1000

80KA, 690V

gG/aM

KA

83.5

800/1000

83.5

800/1000

Rated short-time withstand current(R.M.S)lcw

≤1000V, 0.15s

≤1000V, 0.25s

≤1000V, 1s

KA

KA

KA

38

36

20

38

36

20

Rated short circuit making capacity

≤1000V

KA 

80

80

Rated capacitor power (the capacitor ratings

are limited by the fuse link.)

415V

500V

690V

kVAr

kVAr

kVAr

250

300

450

310

375

550

Power loss/pole

At rated operational current

25

40

Mechanical endurance

 

Oper 

10000

10000

Weight without accessories

3P switch

kg

5.2

5.2

Terminal screw specifications

Terminal tightening torque

Operating torque

Metric thread (diameter*length).

Locking torque requirements.

3-pole isolation switch.

mm

Nm

Nm 

M12/40

50-75

27

M12/40

50-75

27

High Voltage WOT 630A 800A Load Isolating Switch

 

High Voltage WOT 630A 800A Load Isolating Switch

Message Feedback
If you have any enquiry about quotation or cooperation,please free to email us at Winston or use the following enquiry form,Our sales representative will contact you within 24 hous.thank you for your interest in our products.
News Center
The Key Role of Frequency Converter in Electrical
In the vast and ever - evolving field of electrical engineering, the frequency converter has emerged as a transformative and indispensable device. It has revolutionized the way electrical systems oper
2025-06-24
What Are the Key Advantages of Proximity Switches over Traditional Mechanical Switches?
In the world of electrical and automation systems, switches play a crucial role. Two common types you might have heard of are proximity switches and traditional mechanical switches. While mechanical s
2025-05-21
What is a Frequency Inverter and Why is it So Widely Used?
In the realm of modern electrical engineering, frequency inverters are revolutionary devices with extensive applications. But what exactly are they and why have they become so essential?​Understanding
2025-04-27
What is the difference between electrical socket and outdoor electrical socket?
In our daily lives, electrical sockets are everywhere, powering a variety of electrical appliances. However, not all electrical sockets are the same. When it comes to outdoor use, a special socket is
2025-03-17

GET A QUOTE

AFFORDABLE PRICE: AS A MANUFACTURER, WE GIVE YOU FACTORY PRICE
Contact Us For Free Sample
×