Have any questions?
CONTACT US
WOT Series 4Pole 40A - 125A Load Switch Disconnector
WOT Series 4Pole 40A - 125A Load Switch Disconnector
WOT Series 4Pole 40A - 125A Load Switch Disconnector
WOT Series 4Pole 40A - 125A Load Switch Disconnector
WOT Series 4Pole 40A - 125A Load Switch Disconnector

WOT Series 4Pole 40A - 125A Load Switch Disconnector

Advantage

> Clean production environment

> Full automatic testing with various tests

> Standardized production process with trained workers

> Low failure ratio and 24-month warranty

> Strong R&D and engineering support

Request a Quote  
WOT Series 4Pole 40A - 125A Load Switch Disconnector
WOT Series 4Pole 40A - 125A Load Switch Disconnector
WOT Series 4Pole 40A - 125A Load Switch Disconnector
WOT Series 4Pole 40A - 125A Load Switch Disconnector
WOT Series 4Pole 40A - 125A Load Switch Disconnector

Product Description

* Load isolating switches are widely applied to distribution system and automation system in building, power, petrochemical and other industries.

* The acceleration mechanism with instantaneous release of spring storage achieves fast connection or separation, which has nothing to do with the speed of operation handle, and greatly improves the ability of extinguishing arc.

* The shell made of glass fiber reinforced unsaturated polyester resin has good flame retardancy, dielectric properties, carbonization resistance and impact resistance.

* The parallel double breakpoint contact has self cleaning effect.

* All contact materials are copper plated silver alloy with two separate contact surfaces.

* The distance is large.

* In the "O" position, you can use three locks to lock the handle at the same time, and reliably avoid misoperation.

* The switch is beautiful, novel and concise, with small volume and complete function.

Compact structure Excellent performance

The most compact isolation solution

Technical data

Model

 

 

WOT40F

WOT63F

WOT80F

WOT100F

WOT125F

Rated insulation voltage and raged operational voltage AC20/DC20

Dielectric strength

Rated impulse withstand voltage

Pollution degree 3

50Hz 1min.

V

KV

KV

750

6

8

750

6

8

750

6

8

750

6

8

750

6

8

Rated thermal current and rated operational current AC20/DC20

...with minimum conductor cross section

Ambient 40°C

Ambient 40°C

Ambient 60°C

Cu

A

A

A

mm⊃2;

40

40

32

10

63

63

50

16

80

80

63

25

115

115

80

35

125

125

100

50

Rated operational current, AC-21A

up to 415V

440...690V

A

A

40

40

63

63

80

80

100

100

125

125

Rated operational current, AC-22A

up to 415V

440...690V

A

A

40

40

63

63

80

80

100

100

125

125

Rated operational current, AC-23A

up to 415V

440V

500V

690V

A

A

A

A

23

23

23

12

63

63

45

20

75

65

58

20

80

65

60

40

90

78

70

50

Rated operational current/ poles in series,

DC-21A

24...48V

110V

220V

440V

500V

750V

A

A

A

A

A

A

32/1

32/2

32/3

16/4

16/4

32/8

63/1

63/2

63/4

16/4

16/4

80/1

80/2

80/4

16/4

16/4

100/1

100/2

100/4

125/1

125/2

125/4

Rated operational current/ poles in series,

DC-22A

24...48V

110V

220V

440V

750V

A

A

A

A

A

32/1

32/2

32/4

10/4

25/8

63/1

63/2

45/4

10/4

80/1

80/2

45/4

10/4

100/1

100/2

63/4

125/1

125/2

80/4

Rated operational current/ poles in series,

DC-23A

24...48V

110V

220V

440V

750V

A

A

A

A

A

32/1

32/2

32/4

10/4

16/8

63/1

63/2

45/4

10/4

80/1

80/2

45/4

10/4

100/1

100/2

63/4

125/1

125/2

63/4

Rated operational power, AC-23A (These

values are given for guidance and may vary

acc. to the motor manufacturer)

220...240V

400...415V

440...500V

690V

KW

KW

KW

KW

5.5

11

11

11

11

22

22

15

22

37

37

18.5

22

37

37

37

22

45

45

45

Rated breaking capacity, AC-23A

up to 415V

440V

500V

690V

A

A

A

A

184

184

184

96

360

360

360

160

640

448

464

160

640

520

480

320

720

624

560

400

Rated breaking capacity/ poles in series,

DC-23A 

24-48V

110V

220V

A

A

128/1

128/2

128/4

180/1

180/2

180/4

252/1

252/2

180/4

400/1

400/2

252/4

500/1

500/2

252/4

440V

750V 

A

40/4

64/8

40/4

40/4

 

 

Rated conditional short-circuit current Ip

(R.M.S) and corresponding max.allowed

cut-off current îc.

The cut-off current  îc refers to values

listed by fuse manufacturers (single phase

test acc.to IEC60269)

50KA

≤415V 

KA

 

 

 

16.5

125/125

16.5

125/125

100KA

≤500V 

KA

 

 

 

 

 

10KA

≤690V

KA

 

 

 

8.2

125/100

8.2

125/100

50KA

≤690V

KA

 

 

 

10

63/63

10

63/63

Rated short-time withstand current

690V,0.25s

690V, 1s

KA

KA

 

 

 

2.5 

2.5  

Rated short circuit making capacity

690V/500V

KA 

 

 

 

3.6

3.6 

Rated capacitor power (the capacitor ratings

are limited by the fuse link.)

400-415V

kVAr 

 

 

 

40

50

Power loss/pole

At rated operational current

 

 

 

4.0 

6.3 

Mechanical endurance

 

Oper 

 

 

 

20000 

20000 

Weight without accessories

 

kg

kg 

 

 

 

0.36

0.50

0.36

0.50

Cable size

Cu-wire size suitable for terminal clamps

mm⊃2;

AWG 

 

 

 

10-70

8-00 

10-70

8-00

Terminal tightening torque

Operating torque

Counter torque required

3-pole switch-disconnector

Nm

Nm 

 

 

 

6

6

2

 


WOT Series 4Pole 40A - 125A Load Switch Disconnector

Dimension

WOT Series 4Pole 40A - 125A Load Switch Disconnector

 

WOT Series 4Pole 40A - 125A Load Switch Disconnector

Message Feedback
If you have any enquiry about quotation or cooperation,please free to email us at Winston or use the following enquiry form,Our sales representative will contact you within 24 hous.thank you for your interest in our products.
News Center
What is the principle of frequency converter?
In our daily lives, we often take it for granted that appliances simply plug in and work. However, behind the scenes, a key technology often ensures this compatibility: the frequency converter. This device is fundamental to industrial automation, manufacturing, and even international trade. But what exactly is it? How does it work?
2025-10-17
How Can You Properly Maintain a Frequency Converter to Extend Its Service Life?
Many buyers invest in a frequency converter to boost motor efficiency, cut energy costs, and reduce wear on equipment—but they often neglect proper maintenance. Without regular care, even quality units may fail early, causing unexpected downtime and extra repair expenses. This guide breaks down simple, safe steps to keep your unit running reliably.
2025-10-14
What Environments Are Suitable for Using a Frequency Converter?
Many users question which environments can properly support a frequency converter’s operation, as poor surroundings may harm its performance or shorten its lifespan. This article clarifies the right environments for it, helping you identify where the device works stably.
2025-10-09
What Common Industrial Scenarios Are Ideal for Using a Motor Soft Starter?
When electric motors start up, they often generate sudden high currents that can damage equipment, disrupt power grids, or shorten motor lifespan. Understanding which scenarios benefit most from a Motor Soft Starter helps businesses avoid these issues and choose the right solution. This article breaks down key industrial settings where this device adds real value.
2025-09-29

GET A QUOTE

AFFORDABLE PRICE: AS A MANUFACTURER, WE GIVE YOU FACTORY PRICE
Contact Us For Free Sample
Captcha Code
×