Have any questions?
CONTACT US
Underfloor heating thermostat WST12 
Underfloor heating thermostat WST12 
Underfloor heating thermostat WST12 
Underfloor heating thermostat WST12 
Underfloor heating thermostat WST12 

WST12 Underfloor heating thermostat 

Advantage

> Clean production environment

> Full automatic testing with various tests

> Standardized production process with trained workers

> Low failure ratio and 24-month warranty

> Strong R&D and engineering support

Request a Quote  
Underfloor heating thermostat WST12 
Underfloor heating thermostat WST12 
Underfloor heating thermostat WST12 
Underfloor heating thermostat WST12 
Underfloor heating thermostat WST12 

Underfloor heating thermostat WST12

cheaper and high quality 16A 3600W and LED for easy use

double temperature controlling

 

Summary

WST12 is the international universal heating electronic thermostat. It use installation of direct wall and have a wide range of controlling temperature. Fool type control interface is easy to use. LED indicates the working state and it is easy for users to understand operation of the thermostat. It is applicable to the unserfloor heating system of the temperature automatic controlling and provides users with a comfortable, safe, energy-saving and high standard heating environment.

Access to external sensors can realize double temperature double controlling (Built-in sensor measures temperature and external sensor makes the over-temperature protection).

 

Technical parameters  

  • Voltage: 230VAC 50/60Hz
  • Power waste: <2VA
  • Range of temperature: 5°C-40°C
  • Ambient temperature: -5°C-50°C
  • Protective casing: IP20
  • External sensor: B=3380 10K@25°C  Lead length:3M Temperature protection
  • Shell material: Flame-retardant PC
  • Installation height:1.2M
  • Installation location:To be fitted in the surrounding air to flow freely on the wall, shall not be affected by other heat effect(Such as sunlight, windows and doors airflow and wall temperature).

 

External limiting temperature sensor installation:

The casing is buried under the floor, the sensor is arranged inside the casing, ending of casing should be thickened, and put in upper part of the concrete layer. Sensor cable can be instead of other cable to be lengthened to 50 meters. If the extension cable is used two of multi core cable, the rest of the cable can not be used for other equipment power supply (such as heating power cable) so as to avoid the voltage signal to disturb the thermostat. If the extension cable is shielded cable, shielding line should not be grounding. The best way is using independent extension cable and be arranged in a separate casing.

 

Temperature setting and control:

Adjust dial to the temperature which need to be controlled, the controller will automatically track and compare the current environment temperature with the setting temperature. When the environment temperature is higher than the preset temperature, the thermostat will automatically disconnect the heater. When the environment temperature in the current is lower than the setting temperature, the thermostat can automatically connect with the heater.

 

Temperature calibration:

Every thermostat in the factory is calibrated, the user don’t need to calibrate again. If the users need calibrating again, he can unload the thermostat knob. After room temperature is stable, use a thermometer to measure the accurate room temperature, and then anti-clockwise rotate adjusting rod slowly to green light state, keep scale indicating " |" which in on the panel and the corresponding disk temperature value aligned with the pressure regulating disk (please keep disk temperature value and Measured value of thermometer aligned.) 

 

 

Message Feedback
If you have any enquiry about quotation or cooperation,please free to email us at Winston or use the following enquiry form,Our sales representative will contact you within 24 hous.thank you for your interest in our products.
News Center
How can I test the foot switch after install?
To test a foot switch after repair, follow these steps:1. Visual Inspection: Check for any visible damage or loose parts. Make sure all components are correctly placed and secured。2. Connectivity Chec
2024-09-27
Can I repair a damaged foot switch myself?
Repairing a damaged foot switch can be a straightforward process if you have some basic knowledge of electrical systems and the necessary tools. Here are some steps you can follow to repair a foot swi
2024-09-27
Winston Exhibition
nverter, maybe everyone knows that there is such a thing and what it is used for, but
2024-04-25
Chinese frequency inverter manufacturer mainly introduced to you what is an inverter
Inverter, maybe everyone knows that there is such a thing and what it is used for, but if you introduce it to others, most of you may not know how to say it. Because there are many things we know in life but don’t understand it. Of course, I believe that people who understand electricity or decoration industries still know about frequency converters. Next, the Chinese frequency inverter manufacturer mainly introduces to you what is an inverter.
2024-04-22

GET A QUOTE

AFFORDABLE PRICE: AS A MANUFACTURER, WE GIVE YOU FACTORY PRICE
Contact Us For Free Sample
×