ADD-155 24VDC battery charger UPS function Power Supply

ADD-155 24VDC battery charger UPS function Power Supply

Advantage

> Clean production environment

> Full automatic testing with various tests

> Standardized production process with trained workers

> Low failure ratio and 24-month warranty

> Strong R&D and engineering support

Request a Quote  
ADD-155 24VDC battery charger UPS function Power Supply

Features:

Universal AC input / Full range

Protections: Short circuit / Overload / Over voltage

Battery low protections

Cooling by free air convection

100% full load burn-in test

Fixed switching frequency at 45 KHz

2 year warranty

 

SPECIFICATIONS  
MODEL ADD-155A ADD-155B ADD-155C
Outputnumber CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3
DC voltage 13.8V 5V 13.3V 27.6V 5V 27.1V 54 V 5 V 53.5 V
Rated Current 9.5A 3A 0.5A 3A 3A 0.5A 0.2A 4.5A 2.3A
Current Range 0~10.5A 0~3A -------- 0~5A 0~3A --------- 0~2.5A 0~3A ---------
Rated Power 152.75W 152.75W 149.9W
Ripple&Noise 150mVp-p 100mVp-p -------- 200mVp-p 100mVp-p ------- 200mVp-p 100mVp-p --------
Voltage Adj.Range CH1:12~14.5V CH1:24~29V CH1:48~58V
Voltage Tolerance ±2.1% ±0.5% -------- ±1.0% ±0.5% -------- ±1.0% ±5.0% --------
Line Regulation ±1.0% ±2.0% -------- ±1.0% ±2.0% -------- ±1.0% ±0.5% --------
Load Regulation ±1.0% ±3.0% -------- ±1.0% ±3.0% -------- ±1.0% ±2.0% --------
Setup,Rise Time 1000ms, 90ms/230VAC          2000ms, 90ms/115VAC at full load
Hold UpTime 24ms/230VAC          20ms/115VAC at full load
INPUT  
Voltage Range 88~264VAC47~63Hz; 124~370VDC
AC Current 2.5A/115VAC  1.5A/230VAC
Efficiency 78% 81% 81%
Inrush Current Coldstart 20A/115VAC   40A/230VAC
Leakage Current <1mA /240VAC
PROTECTION  
Over Load CH1,CH2:105 ~ 135%          CH3:0.51 ~ 0.9Arated output power 
Protection type:AC Charging Mode:Hiccup mode,recovers automatically after fault condition is removed UPS Mode:Protected by internal fuse
Over Voltage CH1:15.87~18.63V CH1:31.74~37.26V CH1:62.1~72.9V
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Battery Low 10V±0.8V 19.5V±1.5V 39V±2V
ENVIRONMENT  
Working Temp. -10~+60℃(Refer to“Derating Curve”)
Working Humidity 20~90%RH non-condensing
Storage Temp.,Humidity -20~+85℃,10~95%RH
Temp.Coefficient ±0.03%/ ℃(0~50℃ )on CH1 output
Vibration 10~500Hz,2G10min./1cycle,60min.each along X, Y,Z axes
SAFETY &EMC  
Safety Standards Design refer to UL60950-1, TUV EN60950-1
Withstand Voltage I/P-O/P:3KVAC   I/P-FG:1.5KVAC   O/P-FG:0.5KVAC
Isolation Resistance I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC /25℃ /70%RH
EMC Emission Compliance to EN55022(CISPR22) Class B, EN61000-3-2,-3
EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11,EN55024,light industry level, criteria A
OTHERS  
Dimension 119*11*50mm(L*W*H)
Weight 1Kg
Packing 20pcs/12.6Kg/0.75CUFT
NOTE  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meetsEMC directives.
Message Feedback
If you have any enquiry about quotation or cooperation,please free to email us at Winston or use the following enquiry form,Our sales representative will contact you within 24 hous.thank you for your interest in our products.
News Center
What is the principle of frequency converter?
In our daily lives, we often take it for granted that appliances simply plug in and work. However, behind the scenes, a key technology often ensures this compatibility: the frequency converter. This device is fundamental to industrial automation, manufacturing, and even international trade. But what exactly is it? How does it work?
2025-10-17
How Can You Properly Maintain a Frequency Converter to Extend Its Service Life?
Many buyers invest in a frequency converter to boost motor efficiency, cut energy costs, and reduce wear on equipment—but they often neglect proper maintenance. Without regular care, even quality units may fail early, causing unexpected downtime and extra repair expenses. This guide breaks down simple, safe steps to keep your unit running reliably.
2025-10-14
What Environments Are Suitable for Using a Frequency Converter?
Many users question which environments can properly support a frequency converter’s operation, as poor surroundings may harm its performance or shorten its lifespan. This article clarifies the right environments for it, helping you identify where the device works stably.
2025-10-09
What Common Industrial Scenarios Are Ideal for Using a Motor Soft Starter?
When electric motors start up, they often generate sudden high currents that can damage equipment, disrupt power grids, or shorten motor lifespan. Understanding which scenarios benefit most from a Motor Soft Starter helps businesses avoid these issues and choose the right solution. This article breaks down key industrial settings where this device adds real value.
2025-09-29

GET A QUOTE

AFFORDABLE PRICE: AS A MANUFACTURER, WE GIVE YOU FACTORY PRICE
Contact Us For Free Sample
Captcha Code
×