                            | Model | HLG-150-12 | HLG-150-24 | HLG-150-36 | HLG-150-48 | 
| DC output voltage, current | 12V 0~12.5A | 24V 0~6.3A | 36V 0~4.2A | 48V 0~3.2A | 
| Wave and noise | 180mVp-p | 180mVp-p | 200mVp-p | 200mVp-p | 
| Inlet wire stability | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | 
| Load stability | ±2% | ± 0.5% | ± 0.5% | ± 0.5% | 
| Efficiency | 88% | 90% | 90.5% | 91.5% | 
| Adjustable range for DC voltage | ±0% | ±0% | ±0% | ±0% | 
| Input voltage range | 100~264VAC /135~373V DC 47~63Hz | |||
| Impact current | Cold start current 45A/230VAC | |||
| Overload protection | 95%~108% Automatically recover after troubleshooting | |||
| Overvoltage protection | 115%~ 135% Hiccup mode, automatically restored after troubleshooting | |||
| Short circuit protection | Protection type: Hiccup mode, automatically restored after troubleshooting | |||
| Setup, rise, hold up time | 500ms, 30ms, 20ms/230VAC(full load) | |||
| Withstand voltage | I/P-O/P: 1.5kV I/P-FG: 1.5kV O/P-FG: 0.5kV Iminute | |||
| Isolation resistance | I/P-O/P I/P-FG O/P-FG: 100M Ohms / 500VDC/25 C /70%RH | |||
| Working temperature | -20℃ ~+60℃ | |||
| Dimension | 170×69×43mm | |||
| Weight | 0.5kg | |||
| Packing | 39.5×23×26.5CM/30PCS/15kg | |||