Have any questions?
CONTACT US
LPV-35W waterproof led power supply

LPV-35W waterproof led power supply

Advantage

> Clean production environment

> Full automatic testing with various tests

> Standardized production process with trained workers

> Low failure ratio and 24-month warranty

> Strong R&D and engineering support

Request a Quote  
LPV-35W waterproof led power supply

Features:

Constant voltage design

Universal AC input/Full range

Withstand 300VAC surge input for 5 seconds

Protections: short circuit/ over load/ over voltage

Cooling by free air convection

Small and compact size

Fully encapsulated with IP67 level

Fully isolated plastic case

Class IIpower unit, no FG

Class 2 power unit

Pass LPS

Suitable for LED lighting and moving sign applications

100% full load burn-in test

Low cost, high reliability
2 year warranty

 

SPECIFICATION

 

OUTPUT

 

Model

LPV-35-5

LPV-35-12

LPV-35-15

LPV-35-24

LPV-35-36

DC Voltage

5V

12V

15V

24V

36V

Rated Current

5A

3A

2.4A

1.5A

1A

Current Range

0 ~ 6A

0 ~ 3A

0 ~ 2.4A

0 ~ 1.5A

0 ~ 1A

Rated Power

30W

36W

36W

36W

36W

Ripple&Noise

80mVp-p

120mVp-p

120mVp-p

150mVp-p

150mVp-p

Voltage Tolerance

±6.0%

±5.0%

Line Regulation

±1.0%

Load Regulation

±4.0%

±2.0%

Setup,Rise Time

500ms, 20ms/230VAC500ms, 20ms/115VAC at full load

Hold Up Time

50ms/230VAC   16ms/115VAC at full load

 

 

INPUT

 

Voltage Range

90 ~ 264VAC   127 ~ 370VDC

Frequency Range

47 ~ 63Hz

Efficiency

77%

84%

84%

85%

85%

AC Current

1.1A/115VAC   0.57A/230VAC

Inrush Current

Cold Start55A at 230VAC

Leakage Current

0.25mA / 240VAC

 

 

PROTECTION

 

Over Load

110 ~ 150% rated output power

Protectiontype: Hiccup mode, recovers automatically after fault condition is removed

Over Voltage

5.75~6.75V

13.8~16.2V

17.25~20.25V

27.6~32.4V

41.4~48.6V

Protection type: Shut down o/p voltage, re-power on to recover

 

 

ENVIRONMENT

 

Working Temp.

-30 ~ +65℃ (Refer to “Derating Curve”)

Working Humidity

20 ~ 90% RH non-condensing

StorageTemp., Humidity

-40 ~ +80℃, 10 ~ 95% RH

Temp. Coefficient

±0.03%/℃ (0 ~ 45℃)

Vibration

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

 

 

SAFETY &EMC

 

Safety Standards

UL1310 class 2,CAN/CSA No.223-M91,CB IEC61347-2-13, IP67 approved, design refer to TUV EN60950-1

Withstand Voltage

I/P-O/P:3KVAC

Isolation Resistance

I/P-O/P>100M Ohms / 500VDC / 25℃ / 70% RH

EMC Emission

Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A,EN61000-3-3

EMC Immunity

Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, EN55024, light industry level, criteria A

 

 

OTHERS

 

Dimension

148*40*30mm (L*W*H)

Weight

0.34Kg

Packing

40pcs/14.6Kg/0.63CUFT

 

 

NOTE

 

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4.Derating may not be needed under low input voltage. Please check the static characteristics for more details.

Message Feedback
If you have any enquiry about quotation or cooperation,please free to email us at Winston or use the following enquiry form,Our sales representative will contact you within 24 hous.thank you for your interest in our products.
News Center
What is the principle of frequency converter?
In our daily lives, we often take it for granted that appliances simply plug in and work. However, behind the scenes, a key technology often ensures this compatibility: the frequency converter. This device is fundamental to industrial automation, manufacturing, and even international trade. But what exactly is it? How does it work?
2025-10-17
How Can You Properly Maintain a Frequency Converter to Extend Its Service Life?
Many buyers invest in a frequency converter to boost motor efficiency, cut energy costs, and reduce wear on equipment—but they often neglect proper maintenance. Without regular care, even quality units may fail early, causing unexpected downtime and extra repair expenses. This guide breaks down simple, safe steps to keep your unit running reliably.
2025-10-14
What Environments Are Suitable for Using a Frequency Converter?
Many users question which environments can properly support a frequency converter’s operation, as poor surroundings may harm its performance or shorten its lifespan. This article clarifies the right environments for it, helping you identify where the device works stably.
2025-10-09
What Common Industrial Scenarios Are Ideal for Using a Motor Soft Starter?
When electric motors start up, they often generate sudden high currents that can damage equipment, disrupt power grids, or shorten motor lifespan. Understanding which scenarios benefit most from a Motor Soft Starter helps businesses avoid these issues and choose the right solution. This article breaks down key industrial settings where this device adds real value.
2025-09-29

GET A QUOTE

AFFORDABLE PRICE: AS A MANUFACTURER, WE GIVE YOU FACTORY PRICE
Contact Us For Free Sample
Captcha Code
×