Have any questions?
CONTACT US
Hot Selling WST-ACL 5A 380V 50HZ Three Phase Filter Electric Power Capacitor Input Reactor Inductor
Hot Selling WST-ACL 5A 380V 50HZ Three Phase Filter Electric Power Capacitor Input Reactor Inductor
Hot Selling WST-ACL 5A 380V 50HZ Three Phase Filter Electric Power Capacitor Input Reactor Inductor
Hot Selling WST-ACL 5A 380V 50HZ Three Phase Filter Electric Power Capacitor Input Reactor Inductor
Hot Selling WST-ACL 5A 380V 50HZ Three Phase Filter Electric Power Capacitor Input Reactor Inductor

WST-ACL AC Input Reactor

Advantage

> Clean production environment

> Full automatic testing with various tests

> Standardized production process with trained workers

> Low failure ratio and 24-month warranty

> Strong R&D and engineering support

Request a Quote  
Hot Selling WST-ACL 5A 380V 50HZ Three Phase Filter Electric Power Capacitor Input Reactor Inductor
Hot Selling WST-ACL 5A 380V 50HZ Three Phase Filter Electric Power Capacitor Input Reactor Inductor
Hot Selling WST-ACL 5A 380V 50HZ Three Phase Filter Electric Power Capacitor Input Reactor Inductor
Hot Selling WST-ACL 5A 380V 50HZ Three Phase Filter Electric Power Capacitor Input Reactor Inductor
Hot Selling WST-ACL 5A 380V 50HZ Three Phase Filter Electric Power Capacitor Input Reactor Inductor
  •  The power supply to other equipment has obvious interference (interference, overvoltage) 

  •  Voltage imbalance between power supply phases > 1.8% of rated voltage 

  •  Very low impedance line (power transformer for frequency converter rating more than 10 times) 

  •  A large number of frequency converters installed on a line to reduce line current 

  •  Use COS <φ (power factor) to correct capacitance or power factor correction unit

  • Rated working voltage: 380V/440V 50Hz 

  • Rated working current: 5A to 1600A@ 40℃ 

  • Electrical strength: core 1 winding 3000VAC/50Hz/5mA/10s without arc breakdown (factory test) 

  • Insulation resistance: 1000VDC insulation resistance value ≥100MV 

  • Reactor noise: less than 65dB(with the reactor horizontal distance point 1 meter test) 

  • Protection class: IP00 

  • Insulation grade: F grade or above 

  • Product implementation standard: IEC289:1987 reactor 

                                                            GB10229-88 reactor (EQV IEC289:1987) 
                                                            Jb9644-1999 Reactance for semiconductor electric drives

Incoming reactor current (A)
Frequency converter governor power KW
Overall Dimensions L×W×H(mm)
A×B
WST-ACL-8
0.75(1.5)
155*105*140
80*65-10
WST-ACL-10
2.5
155*105*140
80*65-10
WST-ACL-10
4
155*110*140
80*65-10
WST-ACL-15
5.5
155*115*140
80*75-10
WST-ACL-20
7.5
155*120*140
80*75-10
WST-ACL-30
11
155*125*140
80*75-10
WST-ACL-40
15
155*130*140
80*85-10
WST-ACL-50
18.5
155*135*140
80*85-10
WST-ACL-60
22
155*140*140
80*85-10
WST-ACL-80
30
190*145*155
80*85-10
WST-ACL-110
37
190*170*155
80*105-10
WST-ACL-125
45
225*160*215
120*85-12
WST-ACL-150
55
225*150*225
120*80-12
WST-ACL-200
75
225*155*225
120*80-12
WST-ACL-250
90(93)
225*165*225
120*90-12
WST-ACL-280
110
225*170*225
120*90-12
WST-ACL-300
132
260*160*255
135*85-12
WST-ACL-400
160
260*170*255
135*95-12
WST-ACL-450
187
260*175*255
135*95-12
WST-ACL-500
200
260*180*255
135*95-12
WST-ACL-540
220
290*190*305
135*95-12
WST-ACL-600
250
290*200*305
135*105-12
WST-ACL-700
280
290*205*305
135*105-12
WST-ACL-800
315
290*210*305
135*110-12

Message Feedback
If you have any enquiry about quotation or cooperation,please free to email us at Winston or use the following enquiry form,Our sales representative will contact you within 24 hous.thank you for your interest in our products.
News Center
Can a Motor Soft Starter Adapt to Different Motor Scenarios and Simplify Maintenance?
Motors have hidden risks—like repeated small mechanical shocks that shorten their life, or electrical mismatches that fail compliance checks. Old solutions only fix obvious problems, but a Motor Soft Starter is made to tackle these less-noticed issues.
2025-08-29
Why Motor Soft Starter Is a Must-Have for Modern Motor Control?
Motors power almost every industrial and municipal task—from water pumps to factory conveyors. But their start-up process hides big problems: sudden electrical surges that mess with power grids, and harsh mechanical jolts that break equipment. Old-fashioned starting methods only make these issues worse, leading to frequent breakdowns and costly fixes. A Motor Soft Starter is the simple solution to these headaches.
2025-08-25
The Key Role of Frequency Converter in Electrical
In the vast and ever - evolving field of electrical engineering, the frequency converter has emerged as a transformative and indispensable device. It has revolutionized the way electrical systems oper
2025-06-24
What Are the Key Advantages of Proximity Switches over Traditional Mechanical Switches?
In the world of electrical and automation systems, switches play a crucial role. Two common types you might have heard of are proximity switches and traditional mechanical switches. While mechanical s
2025-05-21

GET A QUOTE

AFFORDABLE PRICE: AS A MANUFACTURER, WE GIVE YOU FACTORY PRICE
Contact Us For Free Sample
×