Have any questions?
CONTACT US
SP-150 AC To DC Single Output Switching Power Supply With PFC Function
SP-150 AC To DC Single Output Switching Power Supply With PFC Function
SP-150 AC To DC Single Output Switching Power Supply With PFC Function
SP-150 AC To DC Single Output Switching Power Supply With PFC Function
SP-150 AC To DC Single Output Switching Power Supply With PFC Function
SP-150 AC To DC Single Output Switching Power Supply With PFC Function

SP-150 AC To DC Single Output Switching Power Supply With PFC Function

Advantage

> Clean production environment

> Full automatic testing with various tests

> Standardized production process with trained workers

> Low failure ratio and 24-month warranty

> Strong R&D and engineering support

Request a Quote  
SP-150 AC To DC Single Output Switching Power Supply With PFC Function
SP-150 AC To DC Single Output Switching Power Supply With PFC Function
SP-150 AC To DC Single Output Switching Power Supply With PFC Function
SP-150 AC To DC Single Output Switching Power Supply With PFC Function
SP-150 AC To DC Single Output Switching Power Supply With PFC Function
SP-150 AC To DC Single Output Switching Power Supply With PFC Function
  • Universal AC input/ full range
  • Built-in active PFC function, PF>0.93
  • 100% full load burn-in test
  • Protections: Short circuit/ Over load / Over voltage/Over temperature
  • Built- in constant current limiting circuit
  • LED indicator for power on
  • Remote ON-OFF control (Optional)
  • Fixed switching frequency at PF: 67KHzPWM: 134 KHz
  • 3 years warranty
OUTPUT  
Model SP-150-5 SP-150-7.5 SP-150-12 SP-150-13.5 SP-150-15 SP-150-24 SP-150-27 SP-150-48
DC Voltage 5V 7.5V 12V 13.5V 15V 24V 27V 48V
Rated Current 30A 20A 12.5A 11.2A 10A 6.3A 5.6A 3.2A
Current Range 0-30A 0-20A 0-12.5A 0-11.2A 0-10A 0-6.3A 0-5.6A 0-3.2A
Rated Power 150W 150W 150W 151.2W 150W 150W 151.2W 153.6W
Ripple&Noise 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 250mVp-p
DC Adjustment Range -5%,+10% -5%,+10% -5%,+10% -5%,+10% -5%,+10% -5%,+10% -5%,+10% -5%,+10%
Voltage Tolerance ±2% ±2% ±2% ±2% ±2% ±1% ±1% ±1.0%
Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Setup,Rise,Hold Up Time 600ms,30ms,20ms at full load
INPUT  
Voltage Range 85~264 VAC47-63Hz;120~370VDC
AC Current 2.5A/115 VAC1.2A/230VAC
Power Factor PF>0.93/230VAC,PF>0.98/115VAC at full load
Efficiency 75% 79% 80% 80% 81% 83% 84% 84%
Inrush Current Cold start 40A/230VAC
Leakage Current <2mA/240VAC
PROTECTION  
Over Load 105%-150%
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Over Voltage 110%~135%
Protection type: Shut down o/p voltage, re-power on to recover
Over Temp. TSW1(Power transistor) When temp.in 95±5 ℃ shutdown o/p voltagetemp. <95±5 ℃O/I auto-recovery.
ENVIRONMENT  
Working Temp.Humidity -10℃~+50℃; 20%~90%RH
Storage Temp.Humidity -20℃~+85℃; 10%~95%RH
Temp.Coefficient ±0.03%/℃(0~50℃)
Vibration 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes
SAFETY  
Withstand Voltage I/P-O/P:3KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC
STANDARD  
Safety Standard Design refer to UL1950,TUV EN60950
EMCStandard Design refer to EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024
Dimension 199*99*50mm(L*W*H)
Weight 0.75Kg
NOTE 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
Message Feedback
If you have any enquiry about quotation or cooperation,please free to email us at Winston or use the following enquiry form,Our sales representative will contact you within 24 hous.thank you for your interest in our products.
News Center
Can a Motor Soft Starter Adapt to Different Motor Scenarios and Simplify Maintenance?
Motors have hidden risks—like repeated small mechanical shocks that shorten their life, or electrical mismatches that fail compliance checks. Old solutions only fix obvious problems, but a Motor Soft Starter is made to tackle these less-noticed issues.
2025-08-29
Why Motor Soft Starter Is a Must-Have for Modern Motor Control?
Motors power almost every industrial and municipal task—from water pumps to factory conveyors. But their start-up process hides big problems: sudden electrical surges that mess with power grids, and harsh mechanical jolts that break equipment. Old-fashioned starting methods only make these issues worse, leading to frequent breakdowns and costly fixes. A Motor Soft Starter is the simple solution to these headaches.
2025-08-25
The Key Role of Frequency Converter in Electrical
In the vast and ever - evolving field of electrical engineering, the frequency converter has emerged as a transformative and indispensable device. It has revolutionized the way electrical systems oper
2025-06-24
What Are the Key Advantages of Proximity Switches over Traditional Mechanical Switches?
In the world of electrical and automation systems, switches play a crucial role. Two common types you might have heard of are proximity switches and traditional mechanical switches. While mechanical s
2025-05-21

GET A QUOTE

AFFORDABLE PRICE: AS A MANUFACTURER, WE GIVE YOU FACTORY PRICE
Contact Us For Free Sample
×