Have any questions?
CONTACT US
SP-200 AC to DC Single Output Switching Power Supply With PFC Function
SP-200 AC to DC Single Output Switching Power Supply With PFC Function
SP-200 AC to DC Single Output Switching Power Supply With PFC Function
SP-200 AC to DC Single Output Switching Power Supply With PFC Function
SP-200 AC to DC Single Output Switching Power Supply With PFC Function
SP-200 AC to DC Single Output Switching Power Supply With PFC Function
SP-200 AC to DC Single Output Switching Power Supply With PFC Function

SP-200 AC to DC Single Output Switching Power Supply With PFC Function

Advantage

> Clean production environment

> Full automatic testing with various tests

> Standardized production process with trained workers

> Low failure ratio and 24-month warranty

> Strong R&D and engineering support

Request a Quote  
SP-200 AC to DC Single Output Switching Power Supply With PFC Function
SP-200 AC to DC Single Output Switching Power Supply With PFC Function
SP-200 AC to DC Single Output Switching Power Supply With PFC Function
SP-200 AC to DC Single Output Switching Power Supply With PFC Function
SP-200 AC to DC Single Output Switching Power Supply With PFC Function
SP-200 AC to DC Single Output Switching Power Supply With PFC Function
SP-200 AC to DC Single Output Switching Power Supply With PFC Function
  • Universal AC input/ full range

  • Built-in active PFC function

  • 100% full load burn-in test

  • Protections: Short circuit/ Over load/ Over voltage

  • Built-in constant current limiting circuit

  • LED indicator for power on

  • Fixed switching frequency at PFC: 7KHzPWM:134 KHz

  • 3 years warranty

OUTPUT

 

Model

SP-200-5

SP-200-7.5

SP-200-12

SP-200-13.5

SP-200-15

SP-200-24

SP-200-27

SP-200-48

DC Voltage

5V

7.5V

12V

13.5V

15V

24V

27V

48V

Rated Current

40A

26.7A

16.7A

14.9A

13.4A

8.4A

7.5A

4.2A

Current Range

0-40A

0-26.7A

0-16.7A

0-14.9A

0-13.4A

0-8.4A

0-7.5A

0-4.2A

Rated Power

200W

200.2W

200.4W

201.1W

201W

201.6W

202.5W

201.6W

Ripple&Noise

100mVp-p

100mVp-p

100mVp-p

100mVp-p

100mVp-p

150mVp-p

150mVp-p

250mVp-p

DC Adjustment Range

-5%,+10%

-5%,+10%

-5%,+10%

-5%,+10%

-5%,+10%

-5%,+10%

-5%,+10%

-5%,+10%

Voltage Tolerance

±2%

±2%

±2%

±2%

±2%

±1%

±1%

±1.0%

Line Regulation

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load Regulation

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Setup,Rise,Hold Up Time

600ms,30ms,20ms at full load

INPUT

 

Voltage Range

85~264 VAC47-63Hz;120~370VDC

AC Current

3.5A/115 VAC1.7A/230VAC

Power Factor

PF>0.93/230VAC,PF>0.98/115VAC at full load

Efficiency

71%

76%

79%

80%

81%

83%

83%

84%

Inrush Current

Cold start 40A/230VAC

Leakage Current

<2mA/240VAC

PROTECTION

 

Over Load

105%-150%

Protection type: Constant current limiting, recovers automatically after fault condition is removed

Over Voltage

110%~135%

Protection type: Shut down o/p voltage, re-power on to recover

Over Temp.

TSW1(Power transistor) When temp.in 95±5 ℃ shutdown o/p voltagetemp. <95±5 ℃O/I auto-recovery.

ENVIRONMENT

 

Working Temp.Humidity

-10℃~+50℃; 20%~90%RH

Storage Temp.Humidity

-20℃~+85℃; 10%~95%RH

Temp.Coefficient

±0.03%/℃(0~50℃)

Vibration

10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes

SAFETY

 

Withstand Voltage

I/P-O/P:3KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC

Isolation Resistance

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC

STANDARD

 

Safety Standard

Design refer to UL1950,TUV EN60950

EMCStandard

Designrefer toEN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024

OTHERS

 

Dimension

199*99*50mm (L*W*H)

Weight

0.8Kg/pc

NOTE

1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

Message Feedback
If you have any enquiry about quotation or cooperation,please free to email us at Winston or use the following enquiry form,Our sales representative will contact you within 24 hous.thank you for your interest in our products.
News Center
How can I test the foot switch after install?
To test a foot switch after repair, follow these steps:1. Visual Inspection: Check for any visible damage or loose parts. Make sure all components are correctly placed and secured。2. Connectivity Chec
2024-09-27
Can I repair a damaged foot switch myself?
Repairing a damaged foot switch can be a straightforward process if you have some basic knowledge of electrical systems and the necessary tools. Here are some steps you can follow to repair a foot swi
2024-09-27
Winston Exhibition
nverter, maybe everyone knows that there is such a thing and what it is used for, but
2024-04-25
Chinese frequency inverter manufacturer mainly introduced to you what is an inverter
Inverter, maybe everyone knows that there is such a thing and what it is used for, but if you introduce it to others, most of you may not know how to say it. Because there are many things we know in life but don’t understand it. Of course, I believe that people who understand electricity or decoration industries still know about frequency converters. Next, the Chinese frequency inverter manufacturer mainly introduces to you what is an inverter.
2024-04-22

GET A QUOTE

AFFORDABLE PRICE: AS A MANUFACTURER, WE GIVE YOU FACTORY PRICE
Contact Us For Free Sample
×