Have any questions?
CONTACT US
SD-120 150W Single output DC-DC Converter

SD-120 120W Single output DC-DC Converter

Advantage

> Clean production environment

> Full automatic testing with various tests

> Standardized production process with trained workers

> Low failure ratio and 24-month warranty

> Strong R&D and engineering support

Request a Quote  
SD-120 150W Single output DC-DC Converter

Features:

2:1 wide input range

Protections: Short circuit / Overload / Over voltage

1500VAC I/O isolation

Built-in EMI filter, low ripple noise

100% full load burn-in test

Fixed switching frequency at 83 KHz

24V and 48V input voltage design refer to LVD

Low costHigh reliability

2 years warranty

 

SPECIFICATION
OUTPUT  
Model SD-120B-5 SD-120C-5 SD-120D-5 SD-120B-12 SD-120C-12 SD-120D-12 SD-120B-24 SD-120C-24 SD-120D-24 SD-120B-48 SD-120C-48 SD-120D-48
DC Voltage 5V 12V 24V 48V
Rated Current 24A 10A 5A 2.5A
Current Range 0~24A 0~10A 0~5A 0-2.5A
Rated Power 120W 120W 120W 120W
Ripple&Noise 100mVp-p 120mVp-p 150mVp-p 150mVp-p
Voltage  Adj.Range 4.5~5.5VDC 11~16VDC 23~30VDC 43.2-52.8VDC
Voltage Tolerance ±2.0% ±1.0% ±1.0% ±1.0%
Line Regulation ±0.5% ±0.3% ±0.2% ±0.2%
Load Regulation ±0.5% ±0.3% ±0.2% ±0.2%
Setup, Rise Time 2s,50ms(only D mode) at full load
Hold Up  Time 20ms(only D mode) at full load
   
INPUT  
Voltage Range B:19~36VDC  C:36~72VDC   D:72~144VDC or 85~132VAC
Efficiency 74% 75% 76% 75% 77% 80% 78% 81% 83% 78% 81% 83%
DC Current 4.8A/24V 2.4A/48V 1.8A/96V 4.8A/24V 2.4A/48V 1.8A/96V 4.8A/24V 2.4A/48V 1.8A/96V 4.8A/24V 2.4A/48V 1.8A/96V
Inrush Current D:18A/96VDC
Leakage Current <0.75mA/120VAC(SD-100D)
   
PROTECTION  
Over Load 105~135% rated output power
Protection type: Hiccup mode,recovers automatically after fault condition is removed
Over Voltage 5.75~6.75V/10%load 16.8~20V/10%load 31.5~37.5V/10%load 60.2-79.2/10%load
Protection type:Hiccup mode,recovers automatically after fault condition is removed
   
ENVIRONMENT  
Working Temp. -10~+60℃ (Refer to“Derating Curve”)
Working Humidity 20~90%RH non-condensing
Storage Temp.,Humidity -20~+85℃,10~95%RH
Temp.Coefficient ±0.03%/℃ (0~50℃)
Vibration 10~500Hz,2G 10min./1cycle,60min.each along X, Y, Z axes
   
SAFETY &EMC  
Safety  Standards IEC60950-1CB approved by TUV(for D type only)
Withstand Voltage I/P-O/P:1.5KVAC   I/P-FG:1.5KVAC   O/P-FG:0.5KVAC
Isolation Resistance I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC /25℃ /70%RH
EMC Emission Compliance to EN55022(CISPR22) Class B
EMC Immunity Compliance to EN61000-4-2,3,4,6,8,light industry level,criteria A
   
OTHERS  
Dimension 199*98*38mm(L*W*H)
Weight 0.55Kg
Packing 30pcs/16.5Kg
   
NOTE  
1. All parameters NOT specially mentioned are measured at 24,48,96VDC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
Message Feedback
If you have any enquiry about quotation or cooperation,please free to email us at Winston or use the following enquiry form,Our sales representative will contact you within 24 hous.thank you for your interest in our products.
News Center
What is the principle of frequency converter?
In our daily lives, we often take it for granted that appliances simply plug in and work. However, behind the scenes, a key technology often ensures this compatibility: the frequency converter. This device is fundamental to industrial automation, manufacturing, and even international trade. But what exactly is it? How does it work?
2025-10-17
How Can You Properly Maintain a Frequency Converter to Extend Its Service Life?
Many buyers invest in a frequency converter to boost motor efficiency, cut energy costs, and reduce wear on equipment—but they often neglect proper maintenance. Without regular care, even quality units may fail early, causing unexpected downtime and extra repair expenses. This guide breaks down simple, safe steps to keep your unit running reliably.
2025-10-14
What Environments Are Suitable for Using a Frequency Converter?
Many users question which environments can properly support a frequency converter’s operation, as poor surroundings may harm its performance or shorten its lifespan. This article clarifies the right environments for it, helping you identify where the device works stably.
2025-10-09
What Common Industrial Scenarios Are Ideal for Using a Motor Soft Starter?
When electric motors start up, they often generate sudden high currents that can damage equipment, disrupt power grids, or shorten motor lifespan. Understanding which scenarios benefit most from a Motor Soft Starter helps businesses avoid these issues and choose the right solution. This article breaks down key industrial settings where this device adds real value.
2025-09-29

GET A QUOTE

AFFORDABLE PRICE: AS A MANUFACTURER, WE GIVE YOU FACTORY PRICE
Contact Us For Free Sample
Captcha Code
×