Have any questions?
CONTACT US
SD-120 150W Single output DC-DC Converter

SD-120 120W Single output DC-DC Converter

Advantage

> Clean production environment

> Full automatic testing with various tests

> Standardized production process with trained workers

> Low failure ratio and 24-month warranty

> Strong R&D and engineering support

Request a Quote  
SD-120 150W Single output DC-DC Converter

Features:

2:1 wide input range

Protections: Short circuit / Overload / Over voltage

1500VAC I/O isolation

Built-in EMI filter, low ripple noise

100% full load burn-in test

Fixed switching frequency at 83 KHz

24V and 48V input voltage design refer to LVD

Low costHigh reliability

2 years warranty

 

SPECIFICATION
OUTPUT  
Model SD-120B-5 SD-120C-5 SD-120D-5 SD-120B-12 SD-120C-12 SD-120D-12 SD-120B-24 SD-120C-24 SD-120D-24 SD-120B-48 SD-120C-48 SD-120D-48
DC Voltage 5V 12V 24V 48V
Rated Current 24A 10A 5A 2.5A
Current Range 0~24A 0~10A 0~5A 0-2.5A
Rated Power 120W 120W 120W 120W
Ripple&Noise 100mVp-p 120mVp-p 150mVp-p 150mVp-p
Voltage  Adj.Range 4.5~5.5VDC 11~16VDC 23~30VDC 43.2-52.8VDC
Voltage Tolerance ±2.0% ±1.0% ±1.0% ±1.0%
Line Regulation ±0.5% ±0.3% ±0.2% ±0.2%
Load Regulation ±0.5% ±0.3% ±0.2% ±0.2%
Setup, Rise Time 2s,50ms(only D mode) at full load
Hold Up  Time 20ms(only D mode) at full load
   
INPUT  
Voltage Range B:19~36VDC  C:36~72VDC   D:72~144VDC or 85~132VAC
Efficiency 74% 75% 76% 75% 77% 80% 78% 81% 83% 78% 81% 83%
DC Current 4.8A/24V 2.4A/48V 1.8A/96V 4.8A/24V 2.4A/48V 1.8A/96V 4.8A/24V 2.4A/48V 1.8A/96V 4.8A/24V 2.4A/48V 1.8A/96V
Inrush Current D:18A/96VDC
Leakage Current <0.75mA/120VAC(SD-100D)
   
PROTECTION  
Over Load 105~135% rated output power
Protection type: Hiccup mode,recovers automatically after fault condition is removed
Over Voltage 5.75~6.75V/10%load 16.8~20V/10%load 31.5~37.5V/10%load 60.2-79.2/10%load
Protection type:Hiccup mode,recovers automatically after fault condition is removed
   
ENVIRONMENT  
Working Temp. -10~+60℃ (Refer to“Derating Curve”)
Working Humidity 20~90%RH non-condensing
Storage Temp.,Humidity -20~+85℃,10~95%RH
Temp.Coefficient ±0.03%/℃ (0~50℃)
Vibration 10~500Hz,2G 10min./1cycle,60min.each along X, Y, Z axes
   
SAFETY &EMC  
Safety  Standards IEC60950-1CB approved by TUV(for D type only)
Withstand Voltage I/P-O/P:1.5KVAC   I/P-FG:1.5KVAC   O/P-FG:0.5KVAC
Isolation Resistance I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC /25℃ /70%RH
EMC Emission Compliance to EN55022(CISPR22) Class B
EMC Immunity Compliance to EN61000-4-2,3,4,6,8,light industry level,criteria A
   
OTHERS  
Dimension 199*98*38mm(L*W*H)
Weight 0.55Kg
Packing 30pcs/16.5Kg
   
NOTE  
1. All parameters NOT specially mentioned are measured at 24,48,96VDC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
Message Feedback
If you have any enquiry about quotation or cooperation,please free to email us at Winston or use the following enquiry form,Our sales representative will contact you within 24 hous.thank you for your interest in our products.
News Center
How can I test the foot switch after install?
To test a foot switch after repair, follow these steps:1. Visual Inspection: Check for any visible damage or loose parts. Make sure all components are correctly placed and secured。2. Connectivity Chec
2024-09-27
Can I repair a damaged foot switch myself?
Repairing a damaged foot switch can be a straightforward process if you have some basic knowledge of electrical systems and the necessary tools. Here are some steps you can follow to repair a foot swi
2024-09-27
Winston Exhibition
nverter, maybe everyone knows that there is such a thing and what it is used for, but
2024-04-25
Chinese frequency inverter manufacturer mainly introduced to you what is an inverter
Inverter, maybe everyone knows that there is such a thing and what it is used for, but if you introduce it to others, most of you may not know how to say it. Because there are many things we know in life but don’t understand it. Of course, I believe that people who understand electricity or decoration industries still know about frequency converters. Next, the Chinese frequency inverter manufacturer mainly introduces to you what is an inverter.
2024-04-22

GET A QUOTE

AFFORDABLE PRICE: AS A MANUFACTURER, WE GIVE YOU FACTORY PRICE
Contact Us For Free Sample
×