  • DC input active surge current limiting
  • Wide 4:1~2:1 DC input range (24V:19~72VDC, 96V:72~144VDC)
  • Protections: Short circuit / Overload / Over voltage / Over temperature/Input polarity (by fuse)
  • 2000VAC I/O Isolation
  • Forced air cooling by built-in DC fan with fan speed control function
  • Output OK Signal
  • Built-in remote ON-OFF control
  • Built-in remote sense function
  • 2 years warranty

 

 

OUTPUT  
Model SD-500L-12 SD-500L-24 SD-500L-48 SD-500H-12 SD-500H-24 SD-500H-48
DC Voltage 12V 24V 48V 12V 24V 48V
Rated Current 40A 21A 10.5A 40A 21A 10.5A
Current Range 0 ~ 40A 0 ~ 21A 0 ~ 10.5A 0 ~ 40A 0 ~ 21A 0~10.5A
Rated Power 480W 504W 504W 480W 504W 504V
Ripple & Noise 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p
Voltage Adj. Range 11 ~ 15V 23 ~ 30V 46 ~ 60V 11~ 15V 23 ~ 30V 46 ~ 60V
Voltage Tolerance ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Setup, Rise Time  500ms, 50ms at full load
INPUT  
Voltage Range 19 ~ 72VDC
Efficiency 86% 88% 89% 87% 89% 90%
DC Current 24.2A/19VDC 24.8A/24VDC 12A/48VDC 8A/72VDC  6A/96VDC
Current(AT NO LOAD) Max.0.2A/48VDC Max.0.1A/96VDC
Inrush Current(Typ.) 60A/48VDC 60A/96VDC
PROTECTION  
Over Load 105~125% rated output power
Protection type: Constant current limiting, shut down o/p voltage after about 5 sec., re-power on to recover 
Over Voltage 16~19V 30.8~35.2V 62~68V 16~19V 30.8~35.2V 62~68V
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down
Over Temperature Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION  
Remote on/off Control Please refer to function manual
Output OK Signal Open collector signal low when PSU turns on, max, sink current: 10mA
ENVIRONMENT  
Working Temp. -20 ~ +60℃ (Refer to “Derating Curve”)
Working Humidity 20 ~ 90% RH non-condensing
Storage Temp., Humidity -40 ~ +85℃, 10 ~ 95% RH
Temp. Coefficient ±0.02%/℃ (0 ~ 50℃)
Vibration 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC  
Safety Standards IEC60950-1 CB approved by TUV
Withstand Voltage I/P-O/P:2KVAC   I/P-FG:2KVAC   O/P-FG:0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH
EMC Emission Compliance to EN55022 (CISPR22) Class B
EMC Immunity Compliance to EN61000-4-2,3,4,6,8, light industry level, criteria A
OTHERS  
MIBF 196.3K hrs min.  MIL-HDBK-217F(25℃)
Dimension 215*115*50mm(L*W*H)
Packing 1.15Kg; 12pcs/14.8Kg/0.92CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 48,96VDC input, related load and 25℃ of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uf & 47 uf parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
Message Feedback
If you have any enquiry about quotation or cooperation,please free to email us at Winston or use the following enquiry form,Our sales representative will contact you within 24 hous.thank you for your interest in our products.
News Center
How can I test the foot switch after install?
To test a foot switch after repair, follow these steps:1. Visual Inspection: Check for any visible damage or loose parts. Make sure all components are correctly placed and secured。2. Connectivity Chec
2024-09-27
Can I repair a damaged foot switch myself?
Repairing a damaged foot switch can be a straightforward process if you have some basic knowledge of electrical systems and the necessary tools. Here are some steps you can follow to repair a foot swi
2024-09-27
Winston Exhibition
nverter, maybe everyone knows that there is such a thing and what it is used for, but
2024-04-25
Chinese frequency inverter manufacturer mainly introduced to you what is an inverter
Inverter, maybe everyone knows that there is such a thing and what it is used for, but if you introduce it to others, most of you may not know how to say it. Because there are many things we know in life but don’t understand it. Of course, I believe that people who understand electricity or decoration industries still know about frequency converters. Next, the Chinese frequency inverter manufacturer mainly introduces to you what is an inverter.
2024-04-22

GET A QUOTE

AFFORDABLE PRICE: AS A MANUFACTURER, WE GIVE YOU FACTORY PRICE
Contact Us For Free Sample
×