Have any questions?
CONTACT US
SP-500 AC To DC Single Output Switching Power Supply With PFC Function
SP-500 AC To DC Single Output Switching Power Supply With PFC Function
SP-500 AC To DC Single Output Switching Power Supply With PFC Function
SP-500 AC To DC Single Output Switching Power Supply With PFC Function
SP-500 AC To DC Single Output Switching Power Supply With PFC Function
SP-500 AC To DC Single Output Switching Power Supply With PFC Function

SP-500 AC To DC Single Output Switching Power Supply With PFC Function

Advantage

> Clean production environment

> Full automatic testing with various tests

> Standardized production process with trained workers

> Low failure ratio and 24-month warranty

> Strong R&D and engineering support

Request a Quote  
SP-500 AC To DC Single Output Switching Power Supply With PFC Function
SP-500 AC To DC Single Output Switching Power Supply With PFC Function
SP-500 AC To DC Single Output Switching Power Supply With PFC Function
SP-500 AC To DC Single Output Switching Power Supply With PFC Function
SP-500 AC To DC Single Output Switching Power Supply With PFC Function
SP-500 AC To DC Single Output Switching Power Supply With PFC Function
  • Universal AC input/ full range
  • Built-in active PFC function
  • 100% full load burn-in test
  • Protections: Short circuit/ Over load/ Over voltage
  • Built-in constant current limiting circuit
  • LED indicator for power on 
  • Fixed switching frequency at PFC: 7KHzPWM:134 KHz
  • 3 years warranty

OUTPUT

 

Model

SP-500-12

SP-500-15

SP-500-24

SP-500-27

SP-500-36

SP-500-48

DC Voltage

12V

15V

24V

27V

36V

48V

Rated Current

40A

32A

20A

18A

13.8A

10A

Current Range

0-40A

0-32A

0-20A

0-18A

0-13.8A

0-10A

Rated Power

480W

480W

480W

486W

496W

480W

Ripple&Noise

240mVp-p

240mVp-p

240mVp-p

200mVp-p

200mVp-p

300mVp-p

Voltage Adj. Range

10-13.2V

13.5-18V

20-26.4V

24-30V

32.4-39.6V

41-56V

Voltage Tolerance

±2%

±1%

±1%

±1%

±1%

±1%

Line Regulation

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load Regulation

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Setup,Rise,Hold Up Time

1.5s,50ms,20msat full load

INPUT

 

Voltage Range

88~264VAC47-63Hz;124~370VDC

AC Current

7A/115V3.5A/230V

Efficiency

84%

84%

83%

85.5%

86.5%

87%

Inrush Current

18A/115V 36A/230V

Leakage Current

<3.5mA/240VAC

PROTECTION

 

Over Load

105-135%

Protection type: Constant current limiting, recovers automatically after fault condition is removed

Over Voltage

13.8-16.2V

15.5-18.2V

18-21V

27.6-32.4V

31-36.5V

57.6-67.2V

Over Temp.

≥55℃Fan On≤45℃Fan Off ≥70℃ Output Cutout

ENVIRONMENT

 

Working Temp.Humidity

-10℃~+50℃; 20%~90%RH

Storage Temp.Humidity

-20℃~+85℃; 10%~95%RH

Temp.Coefficient

±0.03%/℃(0~50℃)

Vibration

10~500Hz,2G 10min,/11cycle,60min,each axes

SAFETY

 

Withstand Voltage

I/P-O/P:3KVACI/P-FG:1.5KVACI/P-FG:0.5KVAC

Isolation Resistance

I/P-O/P,I/P-FG,I/P-FG:500VDC/100MΩ

STANDARD

 

Safety Standard

UL1950

EMCStandard

CISPR22(EN 55022),IEC1000-4,2,3,4,5,6,8,11 IEC1000-3-2

OTHERS

 

Dimension

185*120*93mm(L*W*H)

Weight

1.8kg

NOTE

 

1.All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25℃ of ambient temperature.

2.Tolerance:includes set up tolerance,line regulation and load regulation

3.Ripple&noise are measured at 20MHZ of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ&47μ parallel capacitor.

4.Line regulation:min&max voltage of the rated load.

5.Load regulation:load from 0 to 100%

Message Feedback
If you have any enquiry about quotation or cooperation,please free to email us at Winston or use the following enquiry form,Our sales representative will contact you within 24 hous.thank you for your interest in our products.
News Center
How can I test the foot switch after install?
To test a foot switch after repair, follow these steps:1. Visual Inspection: Check for any visible damage or loose parts. Make sure all components are correctly placed and secured。2. Connectivity Chec
2024-09-27
Can I repair a damaged foot switch myself?
Repairing a damaged foot switch can be a straightforward process if you have some basic knowledge of electrical systems and the necessary tools. Here are some steps you can follow to repair a foot swi
2024-09-27
Winston Exhibition
nverter, maybe everyone knows that there is such a thing and what it is used for, but
2024-04-25
Chinese frequency inverter manufacturer mainly introduced to you what is an inverter
Inverter, maybe everyone knows that there is such a thing and what it is used for, but if you introduce it to others, most of you may not know how to say it. Because there are many things we know in life but don’t understand it. Of course, I believe that people who understand electricity or decoration industries still know about frequency converters. Next, the Chinese frequency inverter manufacturer mainly introduces to you what is an inverter.
2024-04-22

GET A QUOTE

AFFORDABLE PRICE: AS A MANUFACTURER, WE GIVE YOU FACTORY PRICE
Contact Us For Free Sample
×