• Single output: power 600W

|
Model |
MS-600-24 |
MS-600-27 |
MS-600-36 |
MS-600-48 |
|
DC output voltage, current |
24V 0~25A |
27V 0~22A |
36V 0~16.5A |
48V 0~12.5A |
|
Wave and noise |
180mVp-p |
200mVp-p |
200mVp-p |
240mVp-p |
|
Inlet wire stability |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
Load stability |
±1% |
±0.5% |
±0.5% |
±0.5% |
|
Efliciency |
88% |
89.5% |
90% |
90% |
|
Adjustable range for DC voltage |
±10% |
±10% |
±10% |
±10% |
|
Input voltage range |
180~264VAC 254~370VDC 47~63Hz |
|||
|
Impact current |
Cold start current 65A/230VAC |
|||
|
Overload protection |
110%~ 135% cut off the output, automatic recovery:Hiccup mode, recovers automatically after fault condition is removed |
|||
|
Over voltage protection |
115%~ 135% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed |
|||
|
Over temperature protection |
Turn off the output and restore normal output after the temperature returns to normal |
|||
|
Setup, rise, hold up time |
600ms, 50ms/230VAC |
|||
|
Withstand vollage |
I/P-O/P: 1.5kV I/P-FG:1.5kV O/P-FG:0.5kV 1minute |
|||
|
Isolation resistance |
I/P-O/P I/P-FG O/P-FG: 100M Ohms /500VDC/25C /70%RH |
|||
|
Working temperature |
-20℃~+60 ℃ |
|||
|
Dimension |
215×115×50mm |
|||
|
Weight |
1.1kg |
|||
|
Packing |
45.5×31.5×26CM/20PCS/22kg |
|||

GET A QUOTE